m8ta
use https for features.
text: sort by
tags: modified
type: chronology
{488} is owned by tlh24.
{1485}
hide / / print
ref: -2015 tags: PaRAC1 photoactivatable Rac1 synapse memory optogenetics 2p imaging mouse motor skill learning date: 10-30-2019 20:35 gmt revision:1 [0] [head]

PMID-26352471 Labelling and optical erasure of synaptic memory traces in the motor cortex

  • Idea: use Rac1, which has been shown to induce spine shrinkage, coupled to a light-activated domain to allow for optogenetic manipulation of active synapses.
  • PaRac1 was coupled to a deletion mutant of PSD95, PSD delta 1.2, which concentrates at the postsynaptic site, but cannot bind to postsynaptic proteins, thus minimizing the undesirable effects of PSD-95 overexpression.
    • PSD-95 is rapidly degraded by proteosomes
    • This gives spatial selectivity.
  • They then exploited the dendritic targeting element (DTE) of Arc mRNA which is selectively targeted and translated in activiated dendritic segments in response to synaptic activation in an an NMDA receptor dependent manner.
    • Thereby giving temporal selectivity.
  • Construct is then PSD-PaRac1-DTE; this was tested on hippocampal slice cultures.
  • Improved sparsity and labelling further by driving it with the Arc promoter.
  • Motor learning is impaired in Arc KO mice; hence inferred that the induction of AS-PaRac1 by the Arc promoter would enhance labeling during learning-induced potentiation.
  • Delivered construct via in-utero electroporation.
  • Observed rotarod-induced learning; the PaRac signal decayed after two days, but the spine volume persisted in spines that showed Arc / DTE hence PA labeled activity.
  • Now, since they had a good label, performed rotarod training followed by (at variable delay) light pulses to activate Rac, thereby suppressing recently-active synapses.
    • Observed both a depression of behavioral performance.
    • Controlled with a second task; could selectively impair performance on one of the tasks based on ordering/timing of light activation.
  • The localized probe also allowed them to image the synapse populations active for each task, which were largely non-overlapping.

{1450}
hide / / print
ref: -2015 tags: conjugate light electron tomography mouse visual cortex fluorescent label UNC cryoembedding date: 03-11-2019 19:37 gmt revision:1 [0] [head]

PMID-25855189 Mapping Synapses by Conjugate Light-Electron Array Tomography

  • Use aligned interleaved immunofluorescence imaging follwed by array EM (FESEM). 70nm thick sections.
  • Of IHC, tissue must be dehydrated & embedded in a resin.
  • However, the dehydration disrupts cell membranes and ultrastructural details viewed via EM ...
  • Hence, EM microscopy uses osmium tetroxide to cross-link the lipids.
  • ... Yet that also disrupt / refolds the poteins, making IHC fail.
  • Solution is to dehydrate & embed at cryo temp, -70C, where the lipids do not dissolve. They used Lowicryl HM-20.
  • We show that cryoembedding provides markedly improved ultrastructure while still permitting multiplexed immunohistochemistry.

{1430}
hide / / print
ref: -2017 tags: calcium imaging seeded iterative demixing light field microscopy mouse cortex hippocampus date: 02-13-2019 22:44 gmt revision:1 [0] [head]

PMID-28650477 Video rate volumetric Ca2+ imaging across cortex using seeded iterative demixing (SID) microscopy

  • Tobias Nöbauer, Oliver Skocek, Alejandro J Pernía-Andrade, Lukas Weilguny, Francisca Martínez Traub, Maxim I Molodtsov & Alipasha Vaziri
  • Cell-scale imaging at video rates of hundreds of GCaMP6 labeled neurons with light-field imaging followed by computationally-efficient deconvolution and iterative demixing based on non-negative factorization in space and time.
  • Utilized a hybrid light-field and 2p microscope, but didn't use the latter to inform the SID algorithm.
  • Algorithm:
    • Remove motion artifacts
    • Time iteration:
      • Compute the standard deviation versus time (subtract mean over time, measure standard deviance)
      • Deconvolve standard deviation image using Richardson-Lucy algo, with non-negativity, sparsity constraints, and a simulated PSF.
      • Yields hotspots of activity, putative neurons.
      • These neuron lcoations are convolved with the PSF, thereby estimating its ballistic image on the LFM.
      • This is converted to a binary mask of pixels which contribute information to the activity of a given neuron, a 'footprint'
        • Form a matrix of these footprints, p * n, S 0S_0 (p pixels, n neurons)
      • Also get the corresponding image data YY , p * t, (t time)
      • Solve: minimize over T ||YST|| 2|| Y - ST||_2 subject to T0T \geq 0
        • That is, find a non-negative matrix of temporal components TT which predicts data YY from masks SS .
    • Space iteration:
      • Start with the masks again, SS , find all sets O kO^k of spatially overlapping components s is_i (e.g. where footprints overlap)
      • Extract the corresponding data columns t it_i of T (from temporal step above) from O kO^k to yield T kT^k . Each column corresponds to temporal data corresponding to the spatial overlap sets. (additively?)
      • Also get the data matrix Y kY^k that is image data in the overlapping regions in the same way.
      • Minimize over S kS^k ||Y kS kT k|| 2|| Y^k - S^k T^k||_2
      • Subject to S k>=0S^k >= 0
        • That is, solve over the footprints S kS^k to best predict the data from the corresponding temporal components T kT^k .
        • They also impose spatial constraints on this non-negative least squares problem (not explained).
    • This process repeats.
    • allegedly 1000x better than existing deconvolution / blind source segmentation algorithms, such as those used in CaImAn

{1389}
hide / / print
ref: -0 tags: photoacoustic tomography mouse imaging q-switched laser date: 05-11-2017 05:23 gmt revision:1 [0] [head]

Single-impulse panoramic photoacoustic computed tomography of small-animal whole-body dynamics at high spatiotemporal resolution

  • Used Q-switched Nd:YAG and Ti:Sapphire lasers to illuminate mice axially (from the top, through a diffuser and conical lens), exciting the photoacuostic effect, from which they were able to image at 125um resolution a full slice of the mouse.
    • I'm surprised at their mode of illumination -- how do they eliminate the out-of-plane photoacoustic effect?
  • Images look low contrast, but structures, e.g. cortical vasculature, are visible.
  • Can image at the rep rate of the laser (50 Hz), and thereby record cardiac and pulmonary rhythms.
  • Suggest that the photoacoustic effect can be used to image brain activity, but spatial and temporal resolution are limited.

{1390}
hide / / print
ref: -0 tags: photoacoustic tomography mouse imaging q-switched laser date: 05-11-2017 05:21 gmt revision:0 [head]

Single-impulse panoramic photoacoustic computed tomography of small-animal whole-body dynamics at high spatiotemporal resolution

  • Used Q-switched Nd:YAG and Ti:Sapphire lasers to illuminate mice axially, exciting the photoacuostic effect, from which they were able to image at 125um resolution a full slice of the mouse.
  • Images look low contrast, but structures, e.g. cortical vasculature, are visible.
  • Can image at the rep rate of the laser (50 Hz), and thereby record cardiac and pulmonary rhythms.
  • Suggest that the photoacoustic effect can be used to image brain activity, but spatial and temporal resolution are limited.