ref: Hochberg-2006.07 tags: BMI Donoghue Utah probe Nature tetraplegia Hochberg 2006 date: 01-23-2013 18:49 gmt revision:4 [3] [2] [1] [0] [head]

PMID-16838014[] Neuronal ensemble control of prosthetic devices by a human with tetraplegia

  • patient was able to talk?
  • 96-channel microelectrode array implanted in arm/hand knob or right precentral gyrus.
  • around 30 units / day observed.
  • 90% of units showed significantly varied firing rates (K-S test) during imagined movements.
  • 2D control. Good pursuit tracking and center-out performance.
  • Used Wiener filter.
  • also see the technology review